Invitrogen™ ArC™ Amine Reactive Compensation Bead Kit (for use with LIVE/DEAD™ Fixable dead cell stain kits), 100 Tests
On demand
Order number :
A10346
Invitrogen™ ArC™ Amine Reactive Compensation Bead Kit (for use with LIVE/DEAD™ Fixable dead cell stain kits), 100 Tests
ArC™ Amine Reactive Compensation Bead Kit is a bead-based compensation tool specifically optimized for use with LIVE/DEAD™ Fixable dead cell stain kits.
Stain Configuration, Surface
Detection Method, Fluorescent
Features
- Ready-to-use control, Unlike other methods that require sample preparation to make compensation controls using cellular material, the ArC Amine Reactive Compensation Bead Kit is ready to use out of the dropper bottle. The kit includes two types of specially modified polystyrene microspheres that have been optimized to react with the amine-reactive dye in the LIVE/DEAD Fixable dead cell stain kits. The ArC reactive beads (Component A) bind any of the amine-reactive dyes and provide a positive signal; the ArC negative beads (Component B) have no reactivity and provide a negative compensation control. This ready-to-use product preserves the original sample material for experiments; precious sample is not used for the creation of compensation controls.
- Accurate and consistent results, Unlike biological controls, which can have variable expression levels depending upon disease or development state, the Arc beads provide a bright, consistent signal (see figure below). Consistency in the staining pattern of compensation controls is important for obtaining the right compensation value. If the signal varies with the control material used, the compensation value can be affected, leading to erroneous results.
How it works
One drop of beads is added to a test tube containing LIVE/DEAD Fixable dead cell stain. After incubation with amine-reactive dye, the beads are washed in staining buffer, a drop of negative control beads is added (if required), and the beads are resuspended and analyzed by flow cytometry. The two components provide a distinct positive bead that is at least 50-fold brighter than the negative beads, which can be used to set compensation.
Content
- 1 vial ArC™ amine reactive beads.
- 1 vial of negative beads.
There are no specifications
There are no report
You May Also Like
Invitrogen™ LIVE/DEAD™ Fixable Near IR (876) Viability Kit, for 808 nm Excitation, 400 Assays
(Ex-work price)
$ 649
$ 649
On demand
Invitrogen™ eBioscience™ Annexin V Apoptosis Detection Kit, FITC, Propidium Iodide, 300 Tests
(Ex-work price)
$ On demand
$ On demand
On demand
Invitrogen™ Click-iT™ Plus EdU Pacific Blue™ Flow Cytometry Assay Kit, 50 Assays
(Ex-work price)
$ On demand
$ On demand
On demand
Invitrogen™ eBioscience™ Cell Proliferation Dye eFluor™ 450, 4 x 500 µg
(Ex-work price)
$ On demand
$ On demand
On demand
Invitrogen™ eBioscience™ Mouse Intracellular (cytoplasmic/cytokine) Protein Flow Cytometry Workflow Kit
(Ex-work price)
$ On demand
$ On demand
On demand
Invitrogen™ LIVE/DEAD™ Fixable Orange (602) Viability Kit, for 561 nm Excitation, 400 Assays
(Ex-work price)
$ 649
$ 649